Copper C14500 is tellurium-bearing free-machining copper — CuTeP, CW118C, often called tellurium copper or PTE. Copper is 99.90% minimum including tellurium, phosphorus and silver, with tellurium at 0.40–0.7% and phosphorus at 0.004–0.012%. The tellurium is almost insoluble in copper and so sits as a finely dispersed second phase; those particles act as internal chip breakers and as a lubricant at the tool tip.

The effect is dramatic and it is the entire reason the grade exists. C14500 has a CDA machinability rating of 85 against 20 for the plain high-conductivity coppers — a step change from one of the worst-machining engineering metals to a genuinely free-cutting one — while still retaining 93% IACS conductivity. If a copper part has to be turned, drilled, slotted, cross-drilled or threaded by cutting rather than rolling, C14500 is the correct grade and the others are a mistake. Exotic Alloy manufactures C14500 fasteners and machined hardware to ASTM B301/B301M for free-cutting copper rod and bar.

Request a Quote
Product Range

Copper C14500 Fasteners Available

Copper C14500 Hex Bolts
Copper C14500
Hex Bolts
Copper C14500 Heavy Hex Bolts
Copper C14500
Heavy Hex Bolts
Copper C14500 Stud Bolts
Copper C14500
Stud Bolts
Copper C14500 Threaded Rods
Copper C14500
Threaded Rods
Copper C14500 Anchor Bolts
Copper C14500
Anchor Bolts
Copper C14500 Hex Nuts
Copper C14500
Hex Nuts
Copper C14500 Washers
Copper C14500
Washers
Copper C14500 Cotter Pins
Copper C14500
Cotter Pins
Copper C14500 Springs
Copper C14500
Springs
Copper C14500 Circlips
Copper C14500
Circlips
Copper C14500 Coated Fasteners
Copper C14500
Coated Fasteners
Copper C14500 Custom Spacers
Copper C14500
Custom Spacers
Technical Data

Copper C14500 Specifications

Chemical Composition — Copper C14500 (wt. %)
ElementMinimum %Maximum %
Copper (Cu), including Te, P and Ag99.90—
Tellurium (Te)0.400.7
Phosphorus (P)0.0040.012
Mechanical Properties — Copper C14500
ConditionUTS (MPa)YS 0.5% EUL (MPa)Elongation (%)Hardness
Annealed, OS050 grain size (rod)221695040 HRF
Annealed, OS015 grain size (rod)228764643 HRF
1/8 Hard, H00 (rod, 13 mm)2622072636 HRF
1/2 Hard, H02 (rod, 13 mm)2962762043 HRF
1/2 Hard, H02 (rod, 25 mm)2902762542 HRF
1/2 Hard, H02 (rod, 50 mm)29026935—
Hard, H04 (rod, 6 mm)3653381054 HRF
Hard, H04 (rod, 13 mm)3313031548 HRF
Hard, H04 (rod, 25 mm)3313032048 HRF
1/8 Hard, H00 (wire)26220720—
1/2 Hard, H02 (wire)3522836—
Hard, H04 (wire)3863523—
Light Drawn, H55 (tube)2762212035 HRB
Physical Properties
Density8.94 g/cm³ (0.323 lb/in³)
Melting Point — Liquidus1080 °C (1976 °F)
Melting Point — Solidus1051 °C (1924 °F)
Electrical Conductivity93% IACS at 20 °C
Electrical Resistivity1.85 µΩ·cm at 20 °C
Thermal Conductivity355 W/m·K at 20 °C
Coefficient of Thermal Expansion17.1 × 10⁻⁶ /°C (20–100 °C)
Specific Heat Capacity385 J/kg·K at 20 °C
Modulus of Elasticity117 GPa
Modulus of Rigidity44 GPa
Machinability Rating85 (C36000 = 100)
Magnetic ResponseNon-magnetic
Equivalent Grades & Standards
UNSEN / CEN DesignationWerkstoff Nr.Common Name
C14500 CuTeP / CW118C 2.1546 Tellurium Copper, Free-Machining Copper, PTE

Key Specifications: ASTM B301/B301M (Free-Cutting Copper Rod, Bar & Shapes) / ASTM B124/B124M (Forging Rod, Bar & Shapes) / ASTM B283/B283M and ASME SB283 (Die Forgings) / ASTM B216 (Refinery Shapes, Tough-Pitch Fire-Refined) / ASME B16.22 (Solder-Joint Pressure Fittings) / ASTM B224 (Classification of Coppers) / SAE J461 and J463 / EN 12164 and EN 12168 (CuTeP rod and hollow rod) / Federal QQ-B-650 (Brazing Alloy).

Where a certified copper bolt or nut is required, the ASTM nonferrous fastener standards F468 and F467 list C11000; C14500 machined fasteners are supplied to ASTM B301/B301M composition and temper with dimensional conformance to the relevant thread and head standard.

Every copper order ships with EN 10204 3.1 certification giving the heat analysis, the temper, the mechanical test results for that temper and section, and the conductivity where it is a specified property. Positive material identification, electrical conductivity testing to ASTM B193, grain-size verification on annealed tempers and ASTM B577 hydrogen-embrittlement testing on tough-pitch material can all be added at order stage.

Machining: this is the grade’s whole purpose. C14500 rates 85 on the CDA machinability scale where free-cutting brass C36000 is 100 and plain copper is 20. The insoluble tellurium dispersion breaks the chip mechanically instead of letting copper’s ductility draw it out, so the gummy stringy swarf, the built-up edge and the torn finish that make the high-conductivity coppers so awkward all largely disappear. Expect short broken chips, clean threads, good hole quality and surface finishes that need no secondary operation, with tool life and cycle times comparable to a free-cutting brass. Conventional free-machining geometry and speeds apply; a sulphurised cutting oil suits it well. Note that the tellurium addition is the reason the grade is not recommended where the part will be welded — see the joining notes below.

Joining: the trade-off for machinability is joining performance. CDA rates C14500 Excellent for soldering but only Good for brazing and Fair for both oxyacetylene and gas-shielded arc welding, with coated metal arc, spot and seam welding not recommended. Tellurium promotes hot cracking in the weld metal, so fusion welding of C14500 should be avoided by design; soldered, brazed or mechanically fastened joints are the right approach. Where a machined copper part must also be welded, consider machining C12000 or C12200 and accepting the slower cycle.

Forming: capacity for cold working and for hot forming are both rated Good — a step below the Excellent of the plain coppers, because the tellurium particles reduce ductility. Moderate cold heading is practical; severe deep drawing and spinning are not. Hot forming is by extrusion and closed-die forging only.

Forming: hot working temperature is 760–870 °C (1400–1600 °F), by extrusion and closed-die forging. Cold working capacity is rated Good, suitable for moderate cold heading and thread rolling but not for severe drawing or spinning.

Heat treatment: C14500 is not hardenable by heat treatment; the tellurium is present as an insoluble dispersion, not a precipitation hardener, and strength comes only from cold work. Annealing is carried out at 425–650 °C (800–1200 °F). A useful practical difference from pure copper is that C14500 softens at a noticeably higher temperature — the tellurium dispersion pins the grain boundaries, so cold-worked strength is retained to around 350 °C where a plain copper would already be recovering. That makes C14500 the better choice for a machined copper part that must hold its temper after soldering or in warm service. Because the oxygen is scavenged by the phosphorus addition, annealing atmosphere is unrestricted and the grade is not susceptible to hydrogen embrittlement.

All of the coppers share the same broad corrosion behaviour, which is excellent in the environments copper is actually bought for. Copper resists fresh and potable water, atmospheric exposure — where it develops the familiar adherent patina and then corrodes at a negligible rate, which is why copper roofing lasts a century — non-oxidising acids free of dissolved oxygen, neutral and alkaline salt solutions, and seawater at moderate flow velocity. It is biostatic, which is the basis of its use in potable plumbing and in antimicrobial touch surfaces.

Its limits are equally consistent. Copper is attacked by oxidising acids — nitric acid rapidly, and sulfuric or hydrochloric acid as soon as oxygen or an oxidising contaminant such as ferric iron is present. It is attacked by oxidising salts, by sulfides and by hydrogen sulfide, which is the limit on copper in sour service and in polluted harbour water. It suffers erosion-corrosion and impingement attack in fast or aerated water — conventionally about 1.2 m/s is the design ceiling for copper tube in seawater, well below what a copper-nickel will take — and it will pit under deposits. Elevated-temperature oxidation in air becomes significant above roughly 200°C.

C14500’s corrosion behaviour is essentially that of pure copper — the tellurium addition is below the level at which it changes general corrosion resistance, and conductivity is still 93% IACS. The one caution is that the tellurium-rich second phase is slightly less noble than the copper matrix, so in an aggressive electrolyte very fine selective attack at those particles is possible; it is not a practical concern in the electrical, instrumentation and plumbing-hardware duties the grade is normally used for.

This grade is immune to the hydrogen embrittlement that limits tough-pitch copper. Because there is no cuprous oxide dispersion in the metal, there is nothing for diffusing hydrogen to reduce, and so no steam generated at the grain boundaries and no intergranular cracking. That immunity is the whole commercial reason for the grade. It can be brazed in a hydrogen or cracked-ammonia furnace, torch-brazed, and run in hydrogen-bearing atmospheres at temperature without the loss of ductility that would wreck C11000 under the same conditions.

Ammonia and amines cause stress-corrosion cracking in copper, and this is the one corrosion mechanism that will fail a copper fastener without warning. A copper component carrying residual or applied tensile stress — and a tightened bolt is exactly that — will crack in moist ammonia, in ammonium compounds, and in the amine corrosion inhibitors used in boiler and steam systems. Nitrites and mercury compounds do the same. The practical consequences are that copper fasteners should not be used in refrigeration plant handling ammonia, in fertiliser service, in amine-treated condensate systems, or anywhere animal waste or decaying organic matter concentrates ammonia; and that where copper has been cold worked and must sit in a borderline environment, a stress-relief anneal to remove residual stress is worthwhile even though it costs some strength.

Copper is galvanically noble, so it damages what it is bolted into. Copper sits well above carbon steel, cast iron, aluminium, zinc and galvanised coatings on the galvanic series. A copper fastener in an aluminium or steel structure will survive, but it will drive rapid corrosion of the surrounding metal, and the small-cathode-is-safe rule works against you here: a small copper bolt in a large aluminium plate is the less damaging geometry, but a copper bolt clamping a thin aluminium or galvanised sheet will eat through it. Copper must be isolated from aluminium and from galvanised steel with insulating washers and sleeves or a barrier coating, which is why aluminium-to-copper electrical connections use bimetallic lugs rather than a direct bolted lap. Copper is, conversely, compatible with the other coppers and bronzes, with the copper-nickels and with Monel.

With copper, temper — not heat treatment — sets the strength. None of the coppers on this hub is hardenable by heat treatment; there is no quench-and-temper and no precipitation cycle to call on. Strength comes almost entirely from cold work, and the temper designation is therefore the single most important thing on the order after the UNS number. The sequence runs from the annealed tempers (O60 soft anneal, or the OS grain-size tempers such as OS025 and OS050, which specify the annealed grain size rather than a strength) up through H00 one-eighth hard, H01 quarter hard, H02 half hard, H04 hard, H06 extra hard, H08 spring and H10 extra spring. Across that range the tensile strength of a plain copper roughly doubles — from about 220 MPa annealed to about 390 MPa at H10 — while elongation collapses from 45–50% to around 4%. A hard temper bought for strength is therefore also a temper that will not take further forming, and cold heading a fastener head is itself cold work: heads are normally formed in an annealed or light temper and the shank drawn to the specified temper, or the part is formed and then the whole fastener left in the as-formed condition. Tell Exotic Alloy the temper you need, or tell us the property you need and we will specify it.

Copper fasteners are not chosen for load. This is the most common specification error in the family, so it is worth stating plainly: even at hard temper a copper bolt develops roughly 330–380 MPa tensile, against 830 MPa for an ordinary ASTM A325 structural bolt and 1040 MPa for a property class 10.9. Copper is specified when the fastener has to carry current, conduct heat, resist a corrosive environment, stay non-magnetic or avoid sparking — and the structural duty is light or carried by something else. Where a copper-coloured fastener is wanted at real strength the answer is a copper alloy — silicon bronze, aluminium bronze or beryllium copper — not one of the high-conductivity coppers here.

Stress relaxation is the companion problem. Copper creeps at modest temperature and under sustained load, so a bolted copper joint loses preload over time; the softer the temper and the warmer the joint, the faster it goes. Electrical connections in copper are therefore designed either to be re-torqued on a schedule, or to use a spring element (a Belleville or conical washer) that takes up the relaxation, or to use C19400 or a copper alloy whose stress-relaxation resistance is far better than that of a pure copper. A copper busbar bolt torqued once and forgotten is a loose, hot joint later.

How this family divides. The seven coppers Exotic Alloy stocks are not interchangeable grades at different price points; each exists to solve one specific problem, and the trade-off is almost always conductivity against something else. C10100 and C10200 are the oxygen-free coppers — buy them for immunity to hydrogen embrittlement and for the highest conductivity, C10100 when electronic-grade purity and vacuum-tightness genuinely matter and C10200 for everything else. C11000 ETP is the workhorse: the cheapest and most available copper, the standard for busbar and electrical hardware, and the only one in the group covered for bolts and nuts by ASTM F468 and F467 — but it is the grade that embrittles in hydrogen. C12000 DLP and C12200 DHP are the phosphorus-deoxidised coppers, bought for weldability and brazeability; C12000 keeps 98% IACS with a low phosphorus residual, while C12200 trades conductivity down to 85% IACS for the best weldability in the family and is the standard plumbing and HVAC copper. C14500 tellurium copper is the free-machining grade — the only sensible choice for a turned or heavily machined copper part. C19400 is the odd one out and the strongest: a copper-iron alloy that reaches 550 MPa and resists stress relaxation, at 65% IACS.

Key Characteristics

  • Machinability rating of 85 against 20 for the plain coppers — free-cutting.
  • Retains 93% IACS electrical conductivity.
  • Tellurium 0.40–0.7% as an insoluble chip-breaking dispersion.
  • Covered by ASTM B301/B301M for free-cutting copper rod and bar.
  • Not hardenable by heat treatment; strength from cold work only.
  • Holds cold-worked strength to around 350 °C — higher than pure copper.
  • Immune to hydrogen embrittlement; thermal conductivity 355 W/m·K.
  • Fusion welding should be avoided — tellurium promotes hot cracking.

Typical Applications

  • Turned and machined electrical fasteners, terminals and contact screws.
  • Screw-machine electrical hardware, connector bodies and pins.
  • Welding torch tips, nozzles, gas nozzles and electrode holders.
  • Resistance welding electrodes, tips and current-carrying machined parts.
  • Transistor bases, motor and transformer components, soldering iron tips.
  • Plumbing and gas fittings, valve bodies and nuts requiring machining.
  • Cross-drilled, slotted and threaded copper parts of all kinds.
  • Sprinkler heads and fire-protection hardware.