Brass C33500 is low leaded brass in flat product form — copper 62.0–65.0% with 0.25–0.7% lead and the balance zinc. It is the sheet and strip counterpart of C33000, giving a machinability rating of 60 while keeping the forming behaviour of a yellow brass.

The grade exists for stamped and formed parts that also need to be drilled, tapped or broached — the lead makes the secondary machining practical without compromising the blanking and forming. Strength runs 317 MPa annealed to 510 MPa hard. It is also supplied as welded, drawn and stress-relieved tube. Exotic Alloy supplies C33500 strip, sheet and formed components.

Request a Quote
Product Range

Brass C33500 Fasteners Available

Brass C33500 Hex Bolts
Brass C33500
Hex Bolts
Brass C33500 Heavy Hex Bolts
Brass C33500
Heavy Hex Bolts
Brass C33500 Stud Bolts
Brass C33500
Stud Bolts
Brass C33500 Threaded Rods
Brass C33500
Threaded Rods
Brass C33500 Anchor Bolts
Brass C33500
Anchor Bolts
Brass C33500 Hex Nuts
Brass C33500
Hex Nuts
Brass C33500 Washers
Brass C33500
Washers
Brass C33500 Cotter Pins
Brass C33500
Cotter Pins
Brass C33500 Springs
Brass C33500
Springs
Brass C33500 Circlips
Brass C33500
Circlips
Brass C33500 Coated Fasteners
Brass C33500
Coated Fasteners
Brass C33500 Custom Spacers
Brass C33500
Custom Spacers
Technical Data

Brass C33500 Specifications

Chemical Composition — Brass C33500 (wt. %)
ElementMinimum %Maximum %
Copper (Cu)62.065.0
Zinc (Zn)Remainder—
Lead (Pb)0.250.7
Iron (Fe) *—0.15
Copper + sum of named elements99.6—
Mechanical Properties — Brass C33500
ConditionUTS (MPa)YS 0.5% EUL (MPa)Elongation (%)Hardness
Flat, 0.070 mm grain OS070317976558 HRF
Flat, 0.050 mm grain OS0503241036264 HRF
Flat, 0.035 mm grain OS0353381175768 HRF
Flat, 0.025 mm grain OS0253521315572 HRF
Flat, 1/4 hard H013722764355 HRB
Flat, 1/2 hard H024213452370 HRB
Flat, hard H04510414880 HRB
Tube, welded drawn stress relieved WR025104148—
Physical Properties
Density8.47 g/cm³
Melting Range899–927 °C (1650–1700 °F)
Electrical Conductivity26% IACS at 20 °C
Thermal Conductivity116 W/m·K at 20 °C
Coefficient of Thermal Expansion20.3 × 10⁻⁶ /°C
Specific Heat Capacity377 J/kg·K at 20 °C
Modulus of Elasticity103 GPa
Modulus of Rigidity39 GPa
StructureSingle-phase alpha — cold formable
Machinability Rating60 (C36000 = 100)
Capacity for Cold WorkingGood
Capacity for Hot FormingPoor
Annealing Temperature427–704 °C (800–1300 °F)
Hardenable by Heat TreatmentNo — strength from cold work only
Magnetic ResponseNon-magnetic
Equivalent Grades & Standards
UNSCDA NumberCDA Alloy NameCommon Name
C33500 CDA 335 Low Leaded Brass Low Leaded Brass, CDA 335

Key Specifications: ASTM B121/B121M / ASTM B453/B453M.

*For flat products the iron limit is 0.10% maximum.

Note on fastener standards: Four brasses on this hub are covered by the ASTM nonferrous fastener standards. ASTM F468 and F467 list C26000 as Cu 260, C27000 as Cu 270, C46200 as Cu 462 and C46400 as Cu 464 — two cartridge and yellow brasses and the two naval brasses. Those four are the grades to specify where a certified brass bolt, hex cap screw, stud or nut is required, and the naval brasses in particular are the sensible default for marine bolting. The other twenty-six grades here are supplied to their mill product standards — ASTM B36, B134, B135, B111, B171, B16, B21 and others as applicable — with thread conformance to the relevant ASME or ISO standard and acceptance criteria agreed on the order.

Brass fasteners are chosen for machinability, corrosion resistance in mild environments, appearance, non-sparking behaviour and electrical conductivity rather than for load: a naval brass bolt develops around 400 MPa against 830 MPa for an ASTM A325 structural steel one. Where higher strength is needed in a copper alloy, see beryllium copper.

Every brass order ships with EN 10204 3.1 certification giving the heat analysis, the temper, and the mechanical test results for the product form and section supplied. Copper, zinc and lead are reported explicitly — copper and zinc set the structure and therefore the dezincification behaviour, and lead governs both machinability and regulatory acceptability. Dezincification testing to ISO 6509, stress-relief treatment, grain-size verification on annealed tempers and positive material identification can all be added at order stage.

Machining: brass spans the entire machinability scale and the grade choice dominates everything else. The unleaded alpha brasses rate 20 to 30 — gummy, prone to built-up edge, producing long stringy swarf. Adding beta phase lifts that to around 40, and adding lead takes it to 60, 70, 90 and finally 100 for C36000. For any part where turning, drilling, slotting or thread cutting dominates the cost, the leaded alpha-beta brasses are the correct choice and the unleaded ones are a false economy. Conventional free-machining geometry and high surface speeds apply; brass generally runs dry or with light lubricant.

Forming: the reverse. Alpha brasses cold form outstandingly — blanking, deep drawing, spinning, bending, cold heading and thread rolling are all straightforward from the annealed condition, with interstage annealing for severe work. Alpha-beta brasses are poor cold formers but excellent hot formers: the beta phase is plastic at forging temperature, which is why hot stamping, hot extrusion and forging brasses all sit above 37% zinc. Match the grade to the process route before anything else.

Joining: brasses solder and braze well across the family and that is the usual route. Arc welding is restricted — zinc volatilises in the arc, causing porosity and fume — and the leaded grades are worse again because lead promotes hot cracking. Zinc oxide fume causes metal fume fever, so extraction is required whenever brass is heated to brazing or welding temperature, and lead fume adds its own requirement on the leaded grades.

Heat treatment: brasses are not hardenable by heat treatment. There is no precipitation reaction to exploit, so strength comes from cold work alone and the temper designation records the degree of reduction — the OS grain-size and O annealed conditions at the soft end, then H00, H01, H02, H04, H06, H08 and H10 as cold work increases. Across that span tensile strength roughly doubles while elongation collapses.

Two thermal treatments matter. Annealing restores the soft, formable condition and is specified by resulting grain size rather than by temperature on flat product — hence the OS015, OS025, OS035, OS050 and OS070 tempers, where the number is the nominal grain size in millimetres. A coarser grain anneals softer and draws better but gives a rougher ‘orange peel’ surface after forming, so the grain size is chosen against the forming severity and the finish required. Stress-relief annealing at a lower temperature removes residual tensile stress while keeping most of the cold-worked strength, and as set out below it is the primary control on season cracking. Specify it as standard on formed parts going into service.

Everything about a brass follows from its zinc content, because zinc decides the crystal structure. Below roughly 35% zinc the alloy is single-phase alpha brass: face-centred cubic, outstandingly ductile, cold formable to severe reductions, and relatively resistant to dezincification. Above roughly 37% zinc a second beta phase appears, and the alloy becomes alpha-beta. That changes three things at once. It becomes stronger and much more readily hot worked — beta is soft and plastic at forging temperature, which is why extrusion and hot stamping brasses all sit in this range. It becomes far more machinable, because the harder beta phase breaks the chip. And it becomes markedly more susceptible to dezincification, because the zinc-rich beta phase corrodes preferentially.

Cold formability runs the other way. An alpha brass such as C26000 cartridge brass will take deep drawing that would crack a Muntz metal. If a part is deep drawn, specify an alpha brass; if it is hot forged or heavily machined, specify an alpha-beta one. The colour changes too, from the red of 95% gilding metal through bronze and gold to the full yellow of the 60/40 alloys.

Dezincification is the characteristic failure mode of brass and the first thing to assess when specifying one. In stagnant, warm, slightly acidic or high-chloride water the zinc is selectively leached out of the alloy, leaving behind a porous, spongy, mechanically worthless copper residue that retains the original shape and dimensions of the part. A dezincified fitting can look perfectly sound and crumble under hand pressure, and plug-type dezincification can perforate a wall while the surrounding metal appears untouched.

Susceptibility tracks structure. Alpha brasses below about 15% zinc are essentially immune; alpha brasses to 35% zinc are moderately resistant; alpha-beta brasses above 37% zinc are the vulnerable ones, because the zinc-rich beta phase goes first. The industry answer is inhibition — a small arsenic, antimony or phosphorus addition that suppresses the mechanism. On this hub, C44400 admiralty brass is inhibited with 0.02–0.10% antimony and C68700 aluminium brass with 0.02–0.06% arsenic, and both are condenser-tube alloys for exactly that reason. Where a brass will see potable water, seawater or any stagnant warm aqueous service, specify an inhibited grade or a dezincification-resistant designation (DZR/CR), and expect to be asked to prove it by ISO 6509 testing.

Season cracking — ammonia stress-corrosion cracking — is brass's other classic failure, and it is named after the monsoon. Cold-worked brass cartridge cases stored in Indian arsenals cracked spontaneously during the humid season, and the cause was traced to traces of ammonia from decomposing organic matter acting on metal carrying high residual tensile stress. The mechanism is unchanged today. Moist ammonia, ammonium compounds, amines, nitrites and mercury compounds will crack a stressed brass component, and the higher the zinc content and the higher the residual stress, the faster it happens.

The control is stress relief, and on brass it is not optional. A low-temperature stress-relief anneal after cold forming — typically a few hundred degrees, well below the recrystallisation range — removes the residual tension while keeping almost all of the cold-worked strength. Specify it as standard on deep-drawn, heavily formed, swaged or tightly threaded brass parts going into service, and treat any brass fastener held under sustained preload in an environment where ammonia or amines may be present as a candidate for cracking.

Lead is what makes brass the most machinable engineering metal there is, and it is also the element now under the most regulatory pressure. Lead is essentially insoluble in the copper-zinc matrix, so it sits as discrete soft globules that break the chip mechanically and lubricate the cutting edge. C36000 free-cutting brass, at 2.5–3.0% lead, is the benchmark against which every other metal's machinability is measured — it is the 100 on the CDA scale, against 20 for pure copper and 30 for an unleaded brass. Nothing else comes close, and the grades on this hub run the whole range from 20 to 100 as lead rises from nil to 3.5%.

The regulatory position has changed and continues to change. Lead in drinking-water-contact components is restricted in most jurisdictions — in the United States under the Safe Drinking Water Act as amended, which cut the wetted-surface limit to a weighted average of 0.25%, and in Europe under the Drinking Water Directive and national acceptance schemes. Lead in electrical and electronic equipment is restricted under RoHS, where the copper-alloy exemption has been progressively narrowed. The practical consequence is that a leaded brass that was specified without question twenty years ago may now be unusable in the same application, and low-lead and lead-free alternatives are displacing it. Confirm the regulatory position for your market and application before committing a design to a leaded brass.

How thirty grades divide. Read the copper figure first; it tells you the structure and almost everything else. The plain alpha brasses run from C21000 at 95% copper — red, ductile, 56% IACS — down through C22000, C22600, C23000 and C24000 to C26000 cartridge brass at 70%, the deep-drawing benchmark, and C26800 and C27000 at 65%. C28000 Muntz metal at 60% copper crosses into alpha-beta, trading cold formability for hot workability and strength. The leaded brasses add machinability in steps — C33000 and C33500 at 60, C34000 and C37000 at 70, C37700 at 80, C34200, C35300 and C38500 at 90, and C35600 and C36000 at 100, the industry benchmark. The tin brasses resist seawater: C44400 admiralty is inhibited alpha brass for condenser tube, while C46400 naval brass and its leaded variants C48200 and C48500 are the marine structural and bolting alloys. Finally three outliers: C68700 aluminium brass and C69400 silicon red brass, which CDA classes as bronzes, and C86300, a cast high-strength manganese bronze reaching 758 MPa.

Key Characteristics

  • Low leaded brass in flat product form — 0.25–0.7% lead.
  • Machinability 60 while keeping yellow-brass forming behaviour.
  • The sheet and strip counterpart of C33000.
  • For stamped parts that also need drilling, tapping or broaching.
  • 317 MPa annealed rising to 510 MPa hard.
  • Also supplied as welded, drawn and stress-relieved tube.
  • 26% IACS electrical conductivity.
  • Iron limited to 0.10% for flat products.

Typical Applications

  • Stamped parts requiring secondary machining.
  • Engraving and nameplate stock.
  • Electrical and instrument hardware.
  • Drilled and tapped formed components.
  • Lock and key components.
  • Fasteners and fixings from strip.
  • Welded and drawn tube products.
  • General machined sheet-metal parts.